Safety lighting: quando l’illuminazione diventa sicurezza

Created in February 01, 2019 in news

Safety lighting: quando l’illuminazione diventa sicurezza

https://www.puntosicuro.it/sicurezza-C-80/pubbliredazionale-C-119/safety-lighting-quando-l-illuminazione-diventa-sicurezza-AR-18761/

Grande successo per Progtech a Light + Building

Created in April 11, 2018 in news

Grande successo per Progtech a Light + Building

Grande successo per Progtech a Light + Building

Dal 18 al 23 marzo, a Francoforte, si è svolta Light + Building, presente anche Progtech con le sue innovative soluzioni di illuminazione per la sicurezza dedicate al carrello elevatore e alla movimentazione [..] Leggi tutto >

SAFETY BAR 20 Blue led lamp for forklifts

Created in October 11, 2017 in news

SAFETY BAR 20 Blue led lamp for forklifts

MADE IN STEEL 2017

Created in March 28, 2017 in news

MADE IN STEEL 2017

We are glad to invited you to our Stand T02 from MADE IN STEEL 2017 Fair.

Seminario sul rischio Fotobiologico

Created in October 27, 2016 in news

Seminario sul rischio Fotobiologico

Qui potete scaricare le slide relative al seminario sull’illuminazione a LED di sicurezza e sul rischio fotobiologico tenutosi alla fiera Ambiente Lavoro di Bologna 2016.

Potete anche vedere il nostro video aziendale sul canale Youtube https://www.youtube.com/channel/UCwnGq6bRm0b5ZJTOYwSIs4A.

Saremo presenti alla Fiera AMBIENTE LAVORO 2016

Created in July 14, 2016 in news

Saremo presenti alla Fiera AMBIENTE LAVORO 2016

Siamo lieti di invitarvi a visitare il nostro stand alla fiera AMBIENTE LAVORO 2016, interamente dedicata alla sicurezza.

In particolare organizzeremo un evento dimostrativo dei nostri corpi illuminanti Venerdì 21 Ottobre.

Vi aspettiamo !!!

DIMMING SYSTEM POWERLINE CARRIER

Created in April 27, 2016 in news

DIMMING SYSTEM POWERLINE CARRIER

The principle based on CARRIER WAVES was applied a long time ago for the management of public / rail and large lighting installations with traditional sources of gas discharge.

The most obvious advantages of the system are to obtain both remote monitoring of consumption and the immediate detection of anomalies of the light fixtures, in order to ensure rapid routine maintenance and scheduling of time ignition slots.

Very little attention was given to dimming, as the gas-discharge light sources required a rather high ignition voltage.

With the advent of LED technology, the special features  of the system have changed radically since the fuel consumption reduces drastically by about 60/70% and the LED light source lasts an average of 50/70 thousand hours, compared to 10,000/20,000 of traditional sources.  Conversely the LED source is dimmable up to 10% of its full power.

PROGTECH,  which has been using the O.C. system for the railway sector for a long time, has taken  advantage of its  leveraged experience gained to offer innovative solutions in the management of their own LED lighting fixtures.

The most obvious benefit found is in being able to implement the dimming and control without making changes to the existing installations, as the O.C. technology  use the supply conductors to transmit signals available from the light fixtures equipped with the power module to the concentrator installed under O.C.

The concentrator collects data sent from all levels, peripheral nodes and serves as a GATEWAY LAN function for the supervision server. It communicates with the server level by direct connection made in LAN/FO, making the signals available from the networks internet / intranet to the customers; representing operator level / interface user for viewing and managing the entire system.

 Another possibility, just as important, which we proposed and tested is, the use of lighting fixtures installed, also for the function of  emergency lighting,  in fact thanks to the possibility to remotely set which fixtures will be appointed to the ignition and in what percentage of power (thanks to dimmable 1:10 V), in case of a blackout, the problem of maintaining or installing dedicated sources with obvious simplification and time saving is less.

In our case it is enough, where the intervention of a rescue group is already provided,  a dimension UPS is foreseen according to the needs of lighting (lux) indicated by the regulations.

Our technical department is available to give any necessary support to customers regarding the system design.

Please find below the architecture of the system

Thanking you for your attention, we remain available for any clarification and / or a meeting to explore the topic.

 best wishes.

SERIE SAFE 10

Created in April 18, 2016 in news

SERIE SAFE 10

LED industrial Lamp created for emergency lighting in any work environment.
This illuminating apparatus emits a blue light "bar” several meters away and can be applied to forklifts to warn the workers of the approaching vehicle; visual signalling is used in noisy environments as it is often the only solution.
The Blue Safe lamp has another useful application on gantry cranes, to signal the passage to the operators.

The device can be powered at 12V, 24V or 220V.

The materials used such as anodized aluminium and stainless steel, make the Blue Safe 10 lamp a durable high quality product.